Ask: the factory has a 24000 of the beer filling line, repeatedly found that sampling bottle after bottle the presence of residual alkali, although on a number of factors were analyzed and measures, but the uninterrupted appearance. Ask the causing factors and the measures to solve?

Answer: alkali 3 tank water into circulating water, guarantee 3 tank water tank of alkali concentration below 0.1%.

 
 
 